bioRxivBiophysics
High-resolution single-particle imaging at 100-200 keV with the Gatan Alpine direct electron detector.
L. M. Chan, B. J. Courteau, A. Maker, M. Wu, B. Basanta, H. Mehmood, D. Bulkley, D. Joyce, B. C. Lee, S. Mick, S. Gulati, G. C. Lander, K. A. Verba
Abstract
Developments in direct electron detector technology have played a pivotal role in enabling high-resolution structural studies by cryo-EM at 200 and 300 keV. Yet, theory and recent experiments indicate advantages to imaging at 100 keV, energies for which the current detectors have not been optimized. In this study, we evaluated the Gatan Alpine detector, designed for operation at 100 and 200 keV. Compared to the Gatan K3, Alpine demonstrated a significant DQE improvement at these voltages, specifically a ~4-fold improvement at Nyquist at 100 keV. In single-particle cryo-EM experiments, Alpine datasets yielded better than 2 [A] resolution reconstructions of apoferritin at 120 and 200 keV on a ThermoFisher Scientific (TFS) Glacios microscope. We also achieved a ~3.2 [A] resolution reconstruction for a 115 kDa asymmetric protein complex, proving its effectiveness with complex biological samples. In-depth analysis revealed that Alpine reconstructions are comparable to K3 reconstructions at 200 keV, and remarkably, reconstruction from Alpine at 120 keV on a TFS Glacios surpassed all but the 300 keV data from a TFS Titan Krios with GIF/K3. Additionally, we show Alpines capability for high-resolution data acquisition and screening on lower-end systems by obtaining ~3 [A] resolution reconstructions of apoferritin and aldolase at 100 keV and detailed 2D averages of a 55 kDa sample using a side-entry cryo holder. Overall, we show that Gatan Alpine performs well with the standard 200 keV imaging systems and may potentially capture the benefits of lower accelerating voltages, possibly bringing smaller sized particles within the scope of cryo-EM.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Single particle cryo-electron microscopy with an enhanced 200 kV cryo-TEM configuration achieves near-atomic resolution
Lijia Jia, Eliza A. Ruben, … Elizabeth V. Wasmuth·bioRxiv·May 7, 2024
- Characterizing the Resolution and Throughput of the Apollo Direct Electron Detector
R. Peng, X. Fu, … S. M. Stagg·bioRxiv·Sep 16, 2022
- Sub-3 A resolution protein structure determination by single-particle cryo-EM at 100 keV
Dimple Karia, Fujiet Koh, … Abhay Kotecha·StructurePeer-reviewed·Jul 30, 2025
- Obtaining high-resolution cryo-EM structures using a common LaB6, 120-keV electron microscope equipped with a sub 200-keV optimised direct electron detector.
Hariprasad Venugopal, Jesse I. Mobbs, … Georg Ramm·Science AdvancesPeer-reviewed·Jan 3, 2025
- Practical considerations for using K3 cameras in CDS mode for high-resolution and high-throughput single particle cryo-EM
M. Sun, C. M. Azumaya, … D. A. Agard·bioRxiv·Nov 8, 2020
- Atomic resolution cryo-EM at 200 keV
Radostin Danev, Haruaki Yanagisawa, … Masahide Kikkawa·IUCrJPeer-reviewed·May 21, 2026