Abstract
Advances in electron detection have been essential to the success of high-resolution cryo-EM structure determination. A new generation of direct electron detector called the Apollo, has been developed by Direct Electron. The Apollo uses a novel event-based MAPS detector custom designed for ultra-fast electron counting. We have evaluated this new camera, finding that it delivers high detective quantum efficiency (DQE) and low coincidence loss, enabling high-quality electron counting data acquisition at up to nearly 80 input electrons per pixel per second. We further characterized the performance of Apollo for single particle cryo-EM on real biological samples. Using mouse apoferritin, Apollo yielded better than 1.9 [A] resolution reconstructions at all three tested dose rates from a half-day data collection session each. With longer collection time and improved specimen preparation, mouse apoferritin was reconstructed to 1.66 [A] resolution. Applied to a more challenging small protein aldolase, we obtained a 2.24 [A] resolution reconstruction. The high quality of the map indicates that the Apollo has sufficiently high DQE to reconstruct smaller proteins and complexes with high-fidelity. Our results demonstrate that the Apollo camera performs well across a broad range of dose rates and is capable of capturing high quality data that produce high-resolution reconstructions for large and small single particle samples.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- High-resolution single-particle imaging at 100-200 keV with the Gatan Alpine direct electron detector.
L. M. Chan, B. J. Courteau, … K. A. Verba·bioRxiv·Feb 14, 2024
- Throughput and Resolution with a Next Generation Direct Electron Detector
J. H. Mendez, A. Mehrani, … S. M. Stagg·bioRxiv·May 3, 2019
- Practical considerations for using K3 cameras in CDS mode for high-resolution and high-throughput single particle cryo-EM
M. Sun, C. M. Azumaya, … D. A. Agard·bioRxiv·Nov 8, 2020
- Obtaining high-resolution cryo-EM structures using a common LaB6, 120-keV electron microscope equipped with a sub 200-keV optimised direct electron detector.
Hariprasad Venugopal, Jesse I. Mobbs, … Georg Ramm·Science AdvancesPeer-reviewed·Jan 3, 2025
- Single particle cryo-electron microscopy with an enhanced 200 kV cryo-TEM configuration achieves near-atomic resolution
Lijia Jia, Eliza A. Ruben, … Elizabeth V. Wasmuth·bioRxiv·May 7, 2024
- Sub-3 A resolution protein structure determination by single-particle cryo-EM at 100 keV
Dimple Karia, Fujiet Koh, … Abhay Kotecha·StructurePeer-reviewed·Jul 30, 2025