Journal of Structural BiologyMolecular BiologyPeer-reviewed journal article
Exploring high-resolution cryo-ET and subtomogram averaging capabilities of contemporary DEDs
Martin ObriD, Wim J. H. HageniD, Robert A. DickiD, Lingbo Yu, Abhay KotechaiD, Florian K. M. SchuriD
Abstract
The potential of energy filtering and direct electron detection for cryo-electron microscopy (cryo-EM) image processing has been well documented for single particle analysis (SPA). Here, we assess the performance of recently introduced hardware for cryo-electron tomography (cryo-ET) and subtomogram averaging (STA), an increasingly popular structural determination method for complex 3D specimens. We acquired cryo-ET datasets of EIAV virus-like particles (VLPs) on two contemporary cryo-EM systems equipped with different energy filters and direct electron detectors (DED), specifically a Krios G4, equipped with a cold field emission gun (CFEG), Thermo Fisher Scientific Selectris X energy filter, and a Falcon 4 DED; and a Krios G3i, with a Schottky field emission gun (XFEG), a Gatan Bioquantum energy filter, and a K3 DED. We performed constrained cross-correlation-based STA on equally sized datasets acquired on the respective systems. The resulting EIAV CA hexamer reconstructions show that both systems perform comparably in the 4-6 [A] resolution range. In addition, by employing a recently introduced multiparticle refinement approach, we obtained a reconstruction of the EIAV CA hexamer at 2.9 [A]. Our results demonstrate the potential of the new generation of energy filters and DEDs for STA, and the effects of using different processing pipelines on their STA outcomes.
- Citations
- 34
- FWCI
- 3.85
- Field percentile
- top 6%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Subnanometer-resolution structure determination in situ by a hybrid subtomogram averaging - single particle cryoEM - workflow
R. Sanchez, Y. Zhang, … M. Kudryashev·bioRxiv·Apr 24, 2020
- Obtaining high-resolution cryo-EM structures using a common LaB6, 120-keV electron microscope equipped with a sub 200-keV optimised direct electron detector.
Hariprasad Venugopal, Jesse I. Mobbs, … Georg Ramm·Science AdvancesPeer-reviewed·Jan 3, 2025
- Cost-benefit analysis of cryogenic electron tomography subtomogram averaging of chaperonin MmCpn at near atomic resolution.
Y. Zhao, M. F. Schmid, W. Chiu·bioRxiv·Jan 30, 2024
- Sub-3 A resolution protein structure determination by single-particle cryo-EM at 100 keV
Dimple Karia, Fujiet Koh, … Abhay Kotecha·StructurePeer-reviewed·Jul 30, 2025
- Atomic resolution cryo-EM at 200 keV
Radostin Danev, Haruaki Yanagisawa, … Masahide Kikkawa·IUCrJPeer-reviewed·May 21, 2026
- Single particle cryo-electron microscopy with an enhanced 200 kV cryo-TEM configuration achieves near-atomic resolution
Lijia Jia, Eliza A. Ruben, … Elizabeth V. Wasmuth·bioRxiv·May 7, 2024