Abstract
In cryogenic electron microscopy (cryo-EM), specimen preparation remains a bottleneck despite recent advancements. Classical plunge freezing methods often result in issues like aggregation and preferred orientations at the air/water interface. Many alternative methods have been proposed, but there remains a lack a universal solution, and multiple techniques are often required for challenging samples. Here, we demonstrate the use of lipid nanotubes with nickel NTA headgroups as a platform for cryo-EM sample preparation. His-tagged specimens of interest are added to the tubules, and they can be frozen by conventional plunge freezing. We show that the nanotubes protect samples from the air/water interface and promote a wider range of orientations. The reconstruction of average subtracted tubular regions (RASTR) method allows for the removal of the nanotubule signal from the cryo-EM images resulting in isolated images of specimens of interest. Testing with {beta}-galactosidase validates the methods ability to capture particles at lower concentrations, overcome preferred orientations, and achieve near-atomic resolution reconstructions. Since the nanotubules can be identified and targeted automatically at low magnification, the method enables fully automated data collection. Furthermore, the particles on the tubes can be automatically identified and centered using 2D classification enabling particle picking without requiring prior information. Altogether, our approach that we call specimen preparation on a tube RASTR (SPOT-RASTR) holds promise for overcoming air-water interface and preferred orientation challenges and offers the potential for fully automated cryo-EM data collection and structure determination.
- Citations
- 8
- FWCI
- 1.46
- Field percentile
- top 17%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Overcoming air-water interface induced artifacts in Cryo-EM with protein nanocrates
Matthew C. Jenkins, Daija Bobe, … Mykhailo Kopylov·Nature MethodsPeer-reviewed·Aug 24, 2026
- Amorphous nickel titanium alloy film: a new choice for cryo electron microscopy sample preparation
- Foam film vitrification for cryo-EM
Yue Zhang, Biplob Nandy, … Jan Löwe·Nature CommunicationsPeer-reviewed·Jul 4, 2025
- Plunge freezing tweezers with ultrasonic excitation for reducing preferred particle orientation in cryo-EM
J Hruby, Mischa Flór, … Ulrich Joseph Lorenz·bioRxiv·Oct 4, 2026
- Nickel-NTA lipid-monolayer affinity grids allow for high-resolution structure determination by cryo-EM
Aleksandra Skrajna, Clara Lenger, … Richard W. Baker·Journal of Structural BiologyPeer-reviewed·Oct 11, 2025
- Nanofluidic chips for cryo-EM structure determination from picoliter sample volumes
S. T. Huber, E. Sarajlic, … A. J. Jakobi·bioRxiv·May 25, 2021