bioRxivBiochemistryPreprint
Novel GC-MS/MS Strategy for Fructose Quantification and Stable Isotope Tracing: Development, Validation, and SIM vs MRM Comparison
Melany Ríos-MoralesiD, Florine H.M. WesterbekeiD, Max NieuwdorpiD, Frédéric Maxime VaziD, Dewi van HarskampiD
- Citations
- 0
Abstract
High dietary fructose consumption is a major contributor to the development of obesity and related cardiometabolic diseases, highlighting the need for accurate assessment of fructose metabolism in humans. Stable isotope tracer approaches, such as 13C6-fructose, require highly sensitive and specific analytical methods to quantify both concentrations and isotopic enrichments. In this study, we developed and validated a robust gas chromatography-triple quadrupole mass spectrometry (GC-QQQ)-based method for the simultaneous measurement of unlabeled and 13C6-fructose in human plasma. The method employs oximation and per-acetate derivatization, and demonstrates high specificity and accuracy. Intra- and inter-assay precision were below 10%, with no detectable carry-over, and a lower limit of quantification (LLOQ) of 0.1 nmol/mL for concentration and 0.02 molar percent excess (MPE%) for enrichment and no interference from glucose. We further compared data acquisition using multiple reaction monitoring (MRM) and selected ion monitoring (SIM). MRM showed superior performance at the low concentrations and enrichment levels characteristic of clinical plasma samples, resulting in improved sensitivity and lower LLOQs compared to SIM. Overall, this validated method provides a sensitive and reliable approach for fructose tracer studies in humans. Its application will facilitate robust investigations into fructose metabolism, and its role in metabolic dysregulation and obesity-related disease.
- organism: human
- assay: metabolomics
- research focus: drug response / drug discovery
- research focus: metabolism & bioenergetics
- research focus: benchmarking
- approach: experimental assay
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- A high-resolution mass spectrometry-based method for quantifying insulin-stimulated glucose uptake in mice following an intraperitoneal injection of tracer
Guofang Zhang, Dorothy H. Slentz, … Ashley S. Williams·bioRxiv·Apr 2, 2026
- Glucose uptake in mammalian cells measured by ICP-MS
Natalie J. Norman, Joyce Ghali, … Julio Alberto Landero Figueroa·Microchemical JournalPeer-reviewed·Nov 24, 2022
- Comparison of a GC-Orbitrap-MS with Parallel GC-FID Capabilities for Metabolomics of Human Serum
Biswapriya B. Misra, Ekong Bassey, Michael Olivier·bioRxiv·Aug 20, 2019
- A novel, ultrasensitive approach for quantitative carbohydrate composition and linkage analysis using LC-ESI ion trap tandem mass spectrometry
K. Alagesan, D. Varon Silva, … D. Kolarich·bioRxiv·Nov 24, 2019
- Simultaneous isotope dilution quantification and metabolic tracing of deoxyribonucleotides by liquid chromatography high resolution mass spectrometry
R. Kuskovsky, R. Buj, … N. W. Snyder·bioRxiv·Oct 29, 2018
- LC-MS/MS-PRM Quantification of IgG glycoforms using stable isotope labeled IgG1 Fc glycopeptide standard
M. Sanda, Q. Yang, … R. Goldman·bioRxiv·Aug 2, 2022