QuickStainer: a rapid negative staining device for improved preservation of molecular structure
Vu Nguyen, Ruchi GautamiD, Arun Kumar SomavarapuiD, Debabrata DuttaiD, Aditya Prasad Patra, Jinghua GeiD, Christopher M. YengoiD, Raúl PadróniD, Roger W. CraigiD
Abstract
Negative staining is a widely used technique for observing macromolecules and their assemblies by transmission electron microscopy. It is commonly employed to optimize specimens for cryo-EM. The stain, typically a uranyl salt, surrounds the structure, providing an outline view at about 20 [A] resolution. Many macromolecules are relatively stable and rigid, and negative stain images provide a good representation of their structure. However, some are labile or flexible and their structure or assembly state is altered by binding to the carbon substrate on the grid before specimen staining. In these cases, the negatively stained appearance does not faithfully represent the structure in solution. This problem is reduced when samples are incubated on the carbon surface for short times (5 s) rather than typical times (30-60 s) before staining. To reduce disruption to a minimum, we have developed a rapid negative staining device (QuickStainer) using 3D-printed components, a stepper motor for precisely timed movements, and an Arduino-controlled interface to execute commands. QuickStainer produces consistent, reproducible results, achieving sample incubation times as low as 10 ms before staining. Tests show rapid adherence of molecules to the grid and greatly improved structural preservation of labile specimens compared with standard preparation protocols. The design of QuickStainer can accommodate inclusion of additional steps, such as timed incubation with enzyme substrate, before staining.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 1
- FWCI
- 1.98
- Field percentile
- top 15%
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- A Cryo-EM Grid Preparation Device for Time-Resolved Structural Studies
D. Kontziampasis, D. P. Klebl, … H. D. White·bioRxiv·Mar 4, 2019
- Need for speed: Examining protein behaviour during cryoEM grid preparation at different timescales
D. P. Klebl, M. S. C. Gravett, … s. P. muench·bioRxiv·May 14, 2020
- Nanofluidic chips for cryo-EM structure determination from picoliter sample volumes
S. T. Huber, E. Sarajlic, … A. J. Jakobi·bioRxiv·May 25, 2021
- Foam film vitrification for cryo-EM
Yue Zhang, Biplob Nandy, … Jan Löwe·Nature CommunicationsPeer-reviewed·Jul 4, 2025
- Shake-it-off: A simple ultrasonic cryo-EM specimen preparation device
J. L. Rubinstein, H. Guo, … T. Kwok·bioRxiv·May 9, 2019
- Through-grid wicking enables high-speed cryoEM specimen preparation
Y. Z. Tan, J. L. Rubinstein·Acta Crystallographica Section D Structural BiologyPeer-reviewed·Oct 13, 2020